log in with your account
forgot your password?
New user? Sign up to buy here
Available
Minimum Order: 1 Unit
MAKER : ABB Extended Product Type:AX50-30-11-88 Product ID:1SBL351074R8811 AX50...AX80 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC. These contactors are of the block type design with: – 3 main poles – control circuit: AC operated – add-on auxiliary contact blocks (optional) for side mounting and a wide range of accessories. Number of Main Contacts NO:3 Number of Main Contacts NC:0 Number of Auxiliary Contacts NO:1 Number of Auxiliary Contacts NC:1 Rated Operational Voltage:Auxiliary Circuit 690 V Main Circuit 690 V Rated Frequency (f):Auxiliary Circuit 50 / 60 Hz Main Circuit 50 / 60 Hz Conventional Free-air Thermal Current (Ith):acc. to IEC 60947-4-1, Open Contactors q = 40 °C 100 A Rated Operational Current AC-1 (Ie):(220 / 240 V) 55 °C 85 A (690 V) 40 °C 100 A (690 V) 70 °C 70 A Rated Operational Current AC-3 (Ie):(415 V) 55 °C 50 A (440 V) 55 °C 45 A (500 V) 55 °C 45 A (690 V) 55 °C 35 A (380 / 400 V) 55 °C 50 A (220 / 230 / 240 V) 55 °C 53 A Rated Operational Power AC-3 (Pe):(415 V) 25 kW (440 V) 25 kW (500 V) 30 kW (690 V) 30 kW (380 / 400 V) 22 kW (220 / 230 / 240 V) 15 kW Rated Short-time Withstand Current Low Voltage (Icw):at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 650 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 370 A for 1 s -empty- A Maximum Breaking Capacity:cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1300 A cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 630 A Maximum Electrical Switching Frequency:(AC-1) 600 cycles per hour (AC-3) 600 cycles per hour Rated Insulation Voltage (Ui):acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V Rated Impulse Withstand Voltage (Uimp):Auxiliary Circuit 6 kV Maximum Mechanical Switching Frequency:3600 cycles per hour Rated Control Circuit Voltage (Uc):50 Hz 230 ... 240 V 60 Hz 240 ... 260 V Operate Time:Between Coil De-energization and NC Contact Closing 7 ... 14 ms Between Coil De-energization and NO Contact Opening 4 ... 11 ms Between Coil Energization and NC Contact Opening 7 ... 22 ms Between Coil Energization and NO Contact Closing 8 ... 27 ms Degree of Protection:acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10 IP10
Sabah
You will be logged out in 120 seconds. Do you want to stay signed in?
Create your first shopping list now.