Product Description Specification

 Maker : ABB
Extended Product Type:XT1C 160 TMD 80-800 3p F F
Product ID:1SDA067396R1

C.BREAKER TMAX XT1C 160 FIXED THREE-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMD R 80-800 A

Circuit Breaker Type to be Associated:Power Distribution
Current Type:AC/DC
Electrical Durability:120 cycles per hour
8000 cycle
Mechanical Durability:Nr. Operations 240 cycles per hour
Nr. Operations 25000 cycle
Number of Poles:3
Opening Time:CB with SOR 15 ms
CB with UVR 15 ms
Order Multiple:1 piece
Power Loss:at Rated Operating Conditions per Pole 4.8 W
Product Main Type:SACE Tmax XT
Product Name:Moulded Case Circuit Breaker
Product Type:CB
Rated Current (In):80 A
Rated Frequency (f):50 / 60 Hz
Rated Voltage (Ur):690 V
Rated Impulse Withstand Voltage (Uimp):8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii):800 A
Rated Insulation Voltage (Ui):800 V
Rated Operational Voltage:690 V AC
500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics):(220 V AC) 40 kA
(230 V AC) 40 kA
(240 V AC) 40 kA
(380 V AC) 25 kA
(415 V AC) 25 kA
(440 V AC) 12.5 kA
(500 V AC) 9 kA
(525 V AC) 8 kA
(690 V AC) 4 kA
(250 V DC) 2 Poles in Series 25 kA
(500 V DC) 3 Poles in Series 25 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu):(220 V AC) 40 kA
(230 V AC) 40 kA
(240 V AC) 40 kA
(380 V AC) 25 kA
(415 V AC) 25 kA
(440 V AC) 25 kA
(500 V AC) 18 kA
(525 V AC) 8 kA
(690 V AC) 4 kA
(250 V DC) 2 Poles in Series 25 kA
(500 V DC) 3 Poles in Series 25 kA
Rated Uninterrupted Current (Iu):160 A
Release:TMD
Release Type:TM
RoHS Date:NA
Setting Range:56...80 A
Short-Circuit Performance Level:C
Standards:IEC
Sub-type:XT1
Terminal Connection Type:Fixed Circuit-Breakers
Version:F
Certificates and Declarations (Document Number)
Data Sheet, Technical Information:1SDC210100D0206
1SDC210099D0206
Declaration of Conformity - CE:9AKK106713A5532
Environmental Information:9AKK107991A8215
GL Certificate:1SDL000163R0103
Instructions and Manuals:1SDH000719R0001
LR Certificate:1SDL000163R0100
REACH Declaration:9AKK108466A1425
RoHS Information:9AKK108466A1424
Classifications
ETIM 4:EC000228 - Power circuit-breaker for trafo/generator/installation prot.
ETIM 5:EC000228 - Power circuit-breaker for trafo/generator/installation prot.
ETIM 6:EC000228 - Power circuit-breaker for trafo/generator/installation prot.
ETIM 7:EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 8:EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code:Q
UNSPSC:39120000
WEEE Category:5. Small Equipment (No External Dimension More Than 50 cm)